KSTAR MP RT 1K S 2000VA / 1800W DOUBLE CONVERSION UPS ( 1 YEAR WARRANTY )

Sale!

118,000.00 120,000.00

KSTAR MP RT 1K Double Conversion UPS

  1. Rack/Tower convertible design with online double conversion and full digital control.
  2. Wide input voltage range: 110~300Vac.
  3. Input power factor of 0.99 with power factor correction (PFC).
  4. Selectable output voltage options: 208/220/230/240Vac.
  5. Smart charger design for optimized battery performance.
  6. Maximum charging current expandable to 12A (Long run unit).
  7. Emergency power-off function (EPO).
  8. ECO mode operation for energy-saving.
  9. Generator compatible.
  10. Hot-Swappable battery design.
  11. Cold start capability.
  12. Intelligent fan speed regulation.
  13. Load segment settable (Optional).
  14. Versatile LCD human-computer interface.
  15. Multiple communication interfaces: RS232 (USB/EPO/Relay card/SNMP card optional).
  16. Multiple protection functions: short-circuit, overload, overheat, battery overcharge and over-discharge, output low voltage, and fan fault alarm.
Compare
Add to Wishlist
Add to Wishlist
Share
Share
Categories,

    KSTAR MP RT 1K S 2000VA / 1800W DOUBLE CONVERSION UPS SPECIFICATION:

    Model MP RT 1k S
    Capacity 2000VA / 1800W
    INPUT
    – Nominal Voltage 208/220/230/240Vac
    – Input Voltage Range 110300Vac (176280Vac @ 100% load)
    – Frequency Range 40~70Hz (50/60Hz Auto-Sensing)
    – Power Factor ≥0.99
    OUTPUT
    – Output Voltage 208/220/230/240Vac
    – Power Factor 0.9
    – Voltage Regulation ±1%
    – Output Frequency Line Mode: 4654Hz or 5664Hz, Bat. Mode: (50/60±0.1%)Hz
    – Crest Factor 3:01
    – Harmonic Distortion (THDv) ≤3% Linear load, ≤5% Nonlinear load
    – Transfer Time AC mode to Bat.Mode: 0ms, Inverter to Bypass: 4ms (Typical)
    – Output Waveform Pure Sinewave
    EFFICIENCY
    – AC Mode 91%
    – Battery Mode 87%
    BATTERY
    – Battery Number 3
    – Capacity (Standard Unit) 9Ah/12V
    – Typical Recharging Time 4 hours (to 90% of full capacity)
    – Charging Voltage 41.1Vdc±1%
    – Charging Current (Max) 1A
    INDICATORS
    – LED Display Line mode, Bat. mode, ECO mode, Bypass mode, Battery low voltage, Overload & UPS fault
    – LCD Display Input voltage, Input frequency, Output voltage, Output frequency, Load percentage, Battery voltage, Inner temperature & Remaining battery backup time
    ALARM
    – Battery Mode Beeping every 4 seconds
    – Battery Low Beeping every second
    – Overload Beeping twice every second
    – Fault Continuously beeping
    PHYSICAL
    – Dimension (W x D x H) 440 x 460 x 86.5 mm
    – Net Weight 11.3 kg
    ENVIRONMENT
    – Operating Temperature 0°C~40°C
    – Storage Temperature -25°C~55°C
    – Humidity Range 2095%RH @ 040°C (Non-condensing)
    – Altitude <1500m, derating required when >1500m
    – Noise Level <50db at 1 Meter
    STANDARDS
    – Safety IEC/EN62040-1, IEC/EN62477-1
    – EMC IEC/EN62040-2, IEC61000-4-2, IEC61000-4-3, IEC61000-4-4, IEC61000-4-5, IEC61000-4-6, IEC61000-4-8

    Reviews

    There are no reviews yet.

    Be the first to review “KSTAR MP RT 1K S 2000VA / 1800W DOUBLE CONVERSION UPS ( 1 YEAR WARRANTY )”

    Your email address will not be published. Required fields are marked *