KSTAR MP RT 1K S 2000VA / 1800W DOUBLE CONVERSION UPS ( 1 YEAR WARRANTY )
Sale!₨118,000.00 ₨120,000.00
KSTAR MP RT 1K Double Conversion UPS
- Rack/Tower convertible design with online double conversion and full digital control.
- Wide input voltage range: 110~300Vac.
- Input power factor of 0.99 with power factor correction (PFC).
- Selectable output voltage options: 208/220/230/240Vac.
- Smart charger design for optimized battery performance.
- Maximum charging current expandable to 12A (Long run unit).
- Emergency power-off function (EPO).
- ECO mode operation for energy-saving.
- Generator compatible.
- Hot-Swappable battery design.
- Cold start capability.
- Intelligent fan speed regulation.
- Load segment settable (Optional).
- Versatile LCD human-computer interface.
- Multiple communication interfaces: RS232 (USB/EPO/Relay card/SNMP card optional).
- Multiple protection functions: short-circuit, overload, overheat, battery overcharge and over-discharge, output low voltage, and fan fault alarm.
CategoriesElectronics, UPS
KSTAR MP RT 1K S 2000VA / 1800W DOUBLE CONVERSION UPS SPECIFICATION:
Model | MP RT 1k S |
---|---|
Capacity | 2000VA / 1800W |
INPUT | |
– Nominal Voltage | 208/220/230/240Vac |
– Input Voltage Range | 110 |
– Frequency Range | 40~70Hz (50/60Hz Auto-Sensing) |
– Power Factor | ≥0.99 |
OUTPUT | |
– Output Voltage | 208/220/230/240Vac |
– Power Factor | 0.9 |
– Voltage Regulation | ±1% |
– Output Frequency | Line Mode: 46 |
– Crest Factor | 3:01 |
– Harmonic Distortion (THDv) | ≤3% Linear load, ≤5% Nonlinear load |
– Transfer Time | AC mode to Bat.Mode: 0ms, Inverter to Bypass: 4ms (Typical) |
– Output Waveform | Pure Sinewave |
EFFICIENCY | |
– AC Mode | 91% |
– Battery Mode | 87% |
BATTERY | |
– Battery Number | 3 |
– Capacity (Standard Unit) | 9Ah/12V |
– Typical Recharging Time | 4 hours (to 90% of full capacity) |
– Charging Voltage | 41.1Vdc±1% |
– Charging Current (Max) | 1A |
INDICATORS | |
– LED Display | Line mode, Bat. mode, ECO mode, Bypass mode, Battery low voltage, Overload & UPS fault |
– LCD Display | Input voltage, Input frequency, Output voltage, Output frequency, Load percentage, Battery voltage, Inner temperature & Remaining battery backup time |
ALARM | |
– Battery Mode | Beeping every 4 seconds |
– Battery Low | Beeping every second |
– Overload | Beeping twice every second |
– Fault | Continuously beeping |
PHYSICAL | |
– Dimension (W x D x H) | 440 x 460 x 86.5 mm |
– Net Weight | 11.3 kg |
ENVIRONMENT | |
– Operating Temperature | 0°C~40°C |
– Storage Temperature | -25°C~55°C |
– Humidity Range | 20 |
– Altitude | <1500m, derating required when >1500m |
– Noise Level | <50db at 1 Meter |
STANDARDS | |
– Safety | IEC/EN62040-1, IEC/EN62477-1 |
– EMC | IEC/EN62040-2, IEC61000-4-2, IEC61000-4-3, IEC61000-4-4, IEC61000-4-5, IEC61000-4-6, IEC61000-4-8 |